Navien NCB-240/110H Error Codes

Updated · by Aurora Star Tech Inc.

Navien NCB-240/110H error codes and diagnostic codes. The NCB-240/110H is a Navien combi boiler in the Navien NCB-H series.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Navien NCB-240/110H error codes list

CodeMeaningSeverity
AHU connection iconAir handler connectionLow
AHU SH Set TempStatus Information item 5 - AHU SH Set TempLow
Anti-freeze iconAnti-freeze mode activeLow
Approx. Boiler FlowStatus Information item 14 - Approx. Boiler FlowLow
Auto air purge iconAuto air purge runningLow
Boost Interval TimeStatus Information item 27 - Boost Interval TimeLow
Cascade/Main iconCascade main unitLow
Combustion iconBurner combustingLow
DHW demand iconDHW demand presentLow
DHW FlowStatus Information item 15 - DHW FlowLow
DHW operation iconDHW preheat feature activeLow
DHW Set TempStatus Information item 4 - DHW Set TempLow
DHW set temperatureDHW set temperature displayLow
E001Heat exchanger overheatHigh
E003Ignition failureHigh
E004False flame detectedHigh
E012Flame lossHigh
E016Heat exchanger overheat (overheating of heat exchanger)High
E030Exhaust overheat (abnormal exhaust temperature)High
E031Burner overheatHigh
E046Heat exchanger thermistor / overheat sensor faultMedium
E047Exhaust thermistor faultMedium
E060Dual venturi faultMedium
E109Fan motor faultHigh
E110Exhaust blockage / abnormal air pressure (APS)High
E205Heating supply temperature sensor faultMedium
E218Heating return temperature sensor faultMedium
E278External (system) supply sensor not detectedMedium
E279External (system) return sensor not detectedMedium
E351Auto feeder (make-up water) valve faultHigh
E352High water pressureHigh
E353Water pressure sensor faultMedium
E407DHW outlet temperature sensor faultMedium
E421DHW cold water inlet sensor faultMedium
E434Water adjustment (flow control) valve faultMedium
E439No DHW flow detected / flow sensor faultMedium
E441DHW outlet 2 sensor faultMedium
E445Mixing (bypass) valve faultMedium
E515PCB faultHigh
E517DIP switch setting faultMedium
E594EEPROM faultMedium
E615Memory fault (input and memory)Medium
E736Cascade communication faultMedium
E740Outdoor sensor not detectedLow
E761Pump aquastat (pre-heat aquastat) not detectedLow
E762Vent pipe not fully inserted (VID)Critical
E773Improper gas type detectedCritical
E777Low water cutoff (LWCO) activatedHigh
E782Front panel communication faultMedium
E784Zone controller communication faultLow
E786Improper front panelMedium
E788Incorrect gas type settingCritical
Exhaust TempStatus Information item 24 - Exhaust TempLow
Fan Current APSStatus Information item 21 - Fan Current APSLow
Fan Current RPMStatus Information item 19 - Fan Current RPMLow
Fan Target APSStatus Information item 20 - Fan Target APSLow
Fan Target RPMStatus Information item 18 - Fan Target RPMLow
Flame ValueStatus Information item 17 - Flame ValueLow
Flow Control ValveStatus Information item 22 - Flow Control ValveLow
GasStatus Information item 31 - GasLow
Heat CapacityStatus Information item 2 - Heat CapacityLow
High AltitudeStatus Information item 28 - High AltitudeLow
Inlet TempStatus Information item 12 - Inlet TempLow
Main F/W VerStatus Information item 32 - Main F/W VerLow
Mixing ValveStatus Information item 23 - Mixing ValveLow
ModelStatus Information item 30 - ModelLow
Operation StateStatus Information item 1 - Operation StateLow
Outdoor ResetStatus Information item 25 - Outdoor ResetLow
Outdoor Reset CurveStatus Information item 26 - Outdoor Reset CurveLow
Outdoor reset iconOutdoor reset enabledLow
Outdoor TempStatus Information item 13 - Outdoor TempLow
Outdoor temperatureOutdoor temperature displayLow
Outlet2 TempStatus Information item 10 - Outlet2 TempLow
Outlet TempStatus Information item 11 - Outlet TempLow
Panel F/W VerStatus Information item 33 - Panel F/W VerLow
Return TempStatus Information item 7 - Return TempLow
SH Set TempStatus Information item 3 - SH Set TempLow
Space heating demand iconSpace heating demandLow
Space heating set temperatureSpace heating set temperature displayLow
Status InformationStatus Information menuLow
Supply TempStatus Information item 6 - Supply TempLow
Sys Return TempStatus Information item 9 - Sys Return TempLow
Sys Supply TempStatus Information item 8 - Sys Supply TempLow
System check iconSystem check or error neededLow
System pressureSystem pressure displayLow
Water PressureStatus Information item 16 - Water PressureLow
Well PumpStatus Information item 29 - Well PumpLow

Troubleshooting the NCB-240/110H

Navien NCB-240/110H specs and setup data

All Navien Combi Boiler error codes →

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.