Weil-McLain Error Code HF: Outdoor unit EEPROM fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code HF on a heat pump means: Outdoor unit EEPROM fault. It is also called Weil-McLain diagnostic code HF.

Medium severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code HF means for you

Check, then call Your heat pump is reporting: Outdoor unit EEPROM fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code HF mean?

The outdoor unit cannot read good data from its EEPROM.

Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)

Common causes of Weil-McLain code HF

  • Bad EEPROM data
  • EEPROM chip failed
  • Inverter module board failed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code HF

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
H7AC supply voltage protection
H8Pressure sensor fault
H9Zone 2 water temperature sensor (Tw2) fault
HAWater outlet temperature sensor (Tw_out) fault
HbPP three times and Tw_out under 44.6 F
HECommunication fault with Ta / room thermostat transfer board
HHH6 fan fault 10 times in 120 minutes
HPLow pressure in cooling, 3 times in an hour
L0DC compressor inverter module fault
L1DC bus low voltage protection
L2DC bus high voltage protection
L4MCE fault

All Weil-McLain Heat Pump error codes →

Weil-McLain code HF: homeowner questions

What does Weil-McLain code HF mean?

Outdoor unit EEPROM fault. The outdoor unit cannot read good data from its EEPROM.

Is it safe to keep using my heat pump with code HF?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code HF myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code HF comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code HF near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.36. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977