Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code PRG: Startup display – model program number (Furnace)

Updated · by Aurora Star Tech Inc.

Carrier error code PRG on a furnace means: Startup display - model program number. It is also called Carrier diagnostic code PRG.

Low severityFurnace59SC6A · Payne PG96VTA · 59MN7C

Homeowner? What Carrier code PRG means for you

Usually minor Your furnace is reporting: Startup display - model program number. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code PRG mean?

After power-up the 3-digit display alternates between the model program number (PRG) and the software version (uEr). The program number is set at the factory for the furnace and should match the number on the rating plate. After about 60 seconds without button presses it shows the system status instead.

Applies to: 59SC6A, Payne PG96VTA and 59MN7C furnaces (3-digit display control)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code PRG

Show all 25 models

59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--2259SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22PG96VTA30040APG96VTA36040BPG96VTA36060APG96VTA48060BPG96VTA48080BPG96VTA60080CPG96VTA60100CPG96VTA66120D

Other Carrier Furnace codes

CodeMeaning
HttMenu: heating thermostat type
iDlIdle - standby, no demand
inFMenu: program number and software
LED OFFNo amber LED - no power to control
LED ONAmber LED steady on
nonNo faults stored
PriTwinning: primary furnace
PUrComponent test - purge (inducer on)
Rapid FlashReversed 115-V polarity (or twinning phasing)
rStMenu: reset to factory defaults
SECTwinning: secondary furnace
Stored codesRecall stored status codes

All Carrier Furnace error codes →

Carrier code PRG: homeowner questions

What does Carrier code PRG mean?

Startup display - model program number. After power-up the 3-digit display alternates between the model program number (PRG) and the software version (uEr). The program number is set at the factory for the furnace and should match the number on the rating plate. After about 60…

Is it safe to keep using my furnace with code PRG?

Usually yes. Code PRG is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code PRG myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code PRG comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code PRG near me?

Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Carrier 59SC6A installation instructions, On-Board Control Method, p.52; Payne PG96VTAB installation instructions, On-Board Control Method, p.52; Carrier 59MN7C installation instructions, On-Board Control Method, p.46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977