Trane S8V2A040M3PD error codes list

CodeMeaningSeverity
E01Furnace control internal failureHigh
E05Flame sensed when no flame should be presentCritical
E08Low flame signal (still running)Low
E2.1Ignition retries exceeded - flame never proven (1 hour lockout)High
E2.2Flame recycles exceeded - flame lost after lighting (1 hour lockout)High
E2.31st stage gas valve not powered when it should be (10 times)High
E3.11st stage pressure switch (PS1) closed when it should be openMedium
E3.21st stage pressure switch (PS1) open when it should be closedMedium
E3.32nd stage pressure switch (PS2) closed when it should be openMedium
E3.42nd stage pressure switch (PS2) open when it should be closedMedium
E4.0Main high limit openHigh
E4.1Reverse airflow limit openHigh
E4.2Flame rollout switch openCritical
E6.1120 V polarity reversedMedium
E6.2Ground not detectedMedium
E6.3Igniter open or igniter relay faultHigh
E7.11st stage gas valve (MVL) powered with no callCritical
E7.2Redundant relay (HLO output) on with no callCritical
E11Gas valve relay / valve circuit faultHigh
E12Control fuse openMedium
E13Blower motor size / OEM ID mismatchMedium
E14Configuration file errorMedium
E17Blower motor communication errorHigh
E23Menu data not received by combustion micro (CCM)Medium
E24Internal communication error between ACM and CCMMedium
E25Orientation sensor out of rangeLow
E26Return static pressure sensor out of range or not connectedLow
E27Return air thermistor out of range or not connectedLow
E28Supply air thermistor out of range or not connectedLow

Troubleshooting the S8V2A040M3PD

Trane S8V2A040M3PD specs and setup data

All Trane Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.