Navien Error Code E109: Fan motor fault (Boiler)
Navien error code E109 on a boiler means: Fan motor fault. It is also called Navien diagnostic code E109.
Homeowner? What Navien code E109 means for you
Call a technician Your boiler is reporting: Fan motor fault. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code E109 mean?
The combustion fan is not reaching or holding the target speed. Manual action: check the fan and venting.
Applies to: Navien NHB-H (NHB-055H/080H/110H/150H) and NFB-H fire-tube (NFB-175H/200H) condensing boilers
Common causes of Navien code E109
- Fan wiring or hall sensor fault
- Fan motor failure
- Excessive vent restriction or blocked intake
Navien models that use code E109
NFB-175HNFB-200HNHB-055HNHB-080HNHB-110HNHB-150H
Other Navien Boiler codes
All Navien Boiler error codes →
Navien code E109: homeowner questions
What does Navien code E109 mean?
Fan motor fault. The combustion fan is not reaching or holding the target speed. Manual action: check the fan and venting.
Is it safe to keep using my boiler with code E109?
It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Navien code E109 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code E109 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code E109 near me?
Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- No heat or some zones cold All brands · Boiler
- Annual service checklist - Navien NHB-H Navien · Boiler
- No space heat - Navien NHB-H / NFB-H Navien · Boiler
- Relief valve discharging - Navien NHB-H / NFB-H Navien · Boiler
Source: Navien NHB-H Installation and Operation Manual, 11.14 Understanding Error Codes, p.119; Navien NFB-H Installation Manual, 11.7 Understanding Error Codes, p.116; NHB-H User's Information Manual (V1.0 Apr 2024), 5.2, p.24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.