Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code 35: Incorrect operation of device (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code 35 on a furnace means: Incorrect operation of device. It is also called Lennox diagnostic code 35.

High severityFurnace

Homeowner? What Lennox code 35 means for you

Call a technician Your furnace is reporting: Incorrect operation of device. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 35 mean?

The unit did not respond within 15 minutes to a thermostat request to start or stop heating/cooling; a device was disabled by a fault/lockout, or electrical noise from the contactor coil disrupted communication. S30/S40 thermostat alert code 35.

Applies to: Lennox communicating gas furnaces (e.g. SL280UHV/SL280UHNV, EL296UHV) in S30/S40 smart thermostat systems

Common causes of Lennox code 35

  • Device in fault/lockout
  • Electrical noise when the compressor contactor coil energizes
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 35

Show all 38 models

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60CEL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
21Incompatible equipment detected
29Over temperature protection (indoor above 90 F)
30Low temperature protection (below 40 F)
31Lost communication with device
32Device resetting
34Must program unit capacity for device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
39No cooling when requested
40HP heating lockout
41Device control board replaced

All Lennox Furnace error codes →

Lennox code 35: homeowner questions

What does Lennox code 35 mean?

Incorrect operation of device. The unit did not respond within 15 minutes to a thermostat request to start or stop heating/cooling; a device was disabled by a fault/lockout, or electrical noise from the contactor coil disrupted communication. S30/S40 thermostat alert…

Is it safe to keep using my furnace with code 35?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code 35 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 35 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 35 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977