Weil-McLain Error Code H5: Room temperature sensor (Ta) fault (Heat Pump)
Weil-McLain error code H5 on a heat pump means: Room temperature sensor (Ta) fault. It is also called Weil-McLain diagnostic code H5.
Homeowner? What Weil-McLain code H5 means for you
Usually minor Your heat pump is reporting: Room temperature sensor (Ta) fault. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Weil-McLain error code H5 mean?
The control reads a bad signal from the room sensor (Ta). The Ta sensor is in the user interface.
Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)
Common causes of Weil-McLain code H5
- Ta sensor failed
- User interface failed
Weil-McLain models that use code H5
Other Weil-McLain Heat Pump codes
All Weil-McLain Heat Pump error codes →
Weil-McLain code H5: homeowner questions
What does Weil-McLain code H5 mean?
Room temperature sensor (Ta) fault. The control reads a bad signal from the room sensor (Ta). The Ta sensor is in the user interface.
Is it safe to keep using my heat pump with code H5?
Usually yes. Code H5 is normally minor, but if it keeps coming back have it checked.
Can I reset Weil-McLain code H5 myself?
You can try one reset (power off for 30 seconds, then on). If Weil-McLain code H5 comes back, the cause is still there and a licensed technician should check it.
Who can fix Weil-McLain code H5 near me?
Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Blank display at first start-up Weil-McLain · Heat Pump
- Does not switch from DHW back to heat right away Weil-McLain · Heat Pump
- Does not switch from heat to DHW right away Weil-McLain · Heat Pump
- Not enough heat in very cold weather Weil-McLain · Heat Pump
- Pressure relief valve drips Weil-McLain · Heat Pump
- Pressure relief valve opens Weil-McLain · Heat Pump
- Pump noisy (cavitation) Weil-McLain · Heat Pump
- Unit on but not heating or cooling as expected Weil-McLain · Heat Pump
Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.56. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.