Rinnai Wall Furnace: Select remote thermostat mode (01) or control panel mode (02)
Select remote thermostat mode (01) or control panel mode (02) on a Rinnai wall furnace: Control mode 00 is the factory default; 01 is for a wall thermostat kit (do not select without the connection parts); 02 returns to the furnace's own panel. Do not unplug the furnace within two hours of entering remote thermostat mode or it reverts to the factory default.
Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
How to fix select remote thermostat mode (01) or control panel mode (02): step by step
- Furnace plugged in but OFF, Set back feature OFF.
- Hold Economy + Up + Program for 2.5 seconds, then release: 00 shows.
- Press Up to move to 01 or 02.
- Press ON/OFF; the display goes blank and the mode is stored.
If the unit shows an error code, look it up: Rinnai Wall Furnace codes
Models
EX08DTEX11DTEX17DTEX22DTEX22DT-W
More settings shortcuts tips for wall furnace
Source: Rinnai EX08DT/EX11DT Installation and Operation Manual (200000083) and EX17DT/EX22DT (200000084), Remote thermostat p.32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.