Rinnai Wall Furnace: Select the gas code (gas type, altitude, vent length)
Select the gas code (gas type, altitude, vent length) on a Rinnai wall furnace: A codes are natural gas, L codes are propane; digits 1 to 4 pick the altitude band.
Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
How to fix select the gas code (gas type, altitude, vent length): step by step
- With the furnace off, hold the Test Switch on the PC board until it beeps.
- Pick the code with the up and down buttons.
- Press the Test Switch twice to store it; the display goes blank.
If the unit shows an error code, look it up: Rinnai Wall Furnace codes
Models
EX08DTEX11DTEX17DTEX22DTEX22DT-W
More settings shortcuts tips for wall furnace
Source: Rinnai EX08DT/EX11DT Installation and Operation Manual (200000083) and EX17DT/EX22DT (200000084), Table 8 Gas Pressure p.25-26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.