IoT module dead (LED off) on a Navien heat pump: The Wi-Fi/IoT module on the heat pump shows no light.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of iot module dead (led off)

  • Module connector not plugged in properly
  • Failed IoT module

How to fix iot module dead (led off): step by step

  1. Power off at the disconnect and wait for the inverter board to discharge before touching wiring or the PCB.
  2. Reseat the IoT module connector.
  3. Still no LED: replace the IoT module.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Heat Pump codes

Models

NAZ17V36NAZ17V60

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 3.4 Troubleshooting, p.26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.