KeepRite Error Code 1+2: Blower running after power-up (normal) (Furnace)
KeepRite error code 1+2 on a furnace means: Blower running after power-up (normal). It is also called KeepRite diagnostic code 1+2.
Homeowner? What KeepRite code 1+2 means for you
Usually minor Your furnace is reporting: Blower running after power-up (normal). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does KeepRite error code 1+2 mean?
One short and two long flashes. Normal: the blower runs for 90 seconds when power comes back during a heat call, or when the heat call ends during the blower-on delay.
Applies to: KeepRite (F/G)9MXE single-stage and (F/G)9MXT two-stage 95% furnaces
Common causes of KeepRite code 1+2
- Power was restored while W was calling
- Heat call dropped during the blower-on delay
KeepRite models that use code 1+2
G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422A
Other KeepRite Furnace codes
All KeepRite Furnace error codes →
KeepRite code 1+2: homeowner questions
What does KeepRite code 1+2 mean?
Blower running after power-up (normal). One short and two long flashes. Normal: the blower runs for 90 seconds when power comes back during a heat call, or when the heat call ends during the blower-on delay.
Is it safe to keep using my furnace with code 1+2?
Usually yes. Code 1+2 is normally minor, but if it keeps coming back have it checked.
Can I reset KeepRite code 1+2 myself?
You can try one reset (power off for 30 seconds, then on). If KeepRite code 1+2 comes back, the cause is still there and a licensed technician should check it.
Who can fix KeepRite code 1+2 near me?
Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- No heat, control ignores the thermostat - KeepRite (F/G)9MXE KeepRite · Furnace
- No heat, control ignores the thermostat - KeepRite (F/G)9MXT KeepRite · Furnace
- Reading stored codes and component test - KeepRite (F/G)9MXE KeepRite · Furnace
- Reading stored codes and component test - KeepRite (F/G)9MXT KeepRite · Furnace
Source: KeepRite/ICP (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, Fig. 16 troubleshooting flow chart, p.24-25; KeepRite/ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Fig. 16, p.24-25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.