KeepRite Error Code 8: Gas heating lockout – manual reset needed (Furnace)
KeepRite error code 8 on a furnace means: Gas heating lockout - manual reset needed. It is also called KeepRite diagnostic code 8.
Homeowner? What KeepRite code 8 means for you
Stop and call Your furnace is reporting: Gas heating lockout - manual reset needed. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does KeepRite error code 8 mean?
The control has locked out gas heat and will NOT reset itself. Turn power off for 5 minutes, then retry.
Applies to: KeepRite (F/G)9MXE single-stage and (F/G)9MXT two-stage 95% furnaces
Common causes of KeepRite code 8
- Gas valve relay on the board stuck closed
- Gas valve wire miswired or shorted
KeepRite models that use code 8
G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422A
Other KeepRite Furnace codes
All KeepRite Furnace error codes →
KeepRite code 8: homeowner questions
What does KeepRite code 8 mean?
Gas heating lockout - manual reset needed. The control has locked out gas heat and will NOT reset itself. Turn power off for 5 minutes, then retry.
Is it safe to keep using my furnace with code 8?
No. Code 8 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.
Can I reset KeepRite code 8 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix KeepRite code 8 near me?
Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- No heat, control ignores the thermostat - KeepRite (F/G)9MXE KeepRite · Furnace
- No heat, control ignores the thermostat - KeepRite (F/G)9MXT KeepRite · Furnace
- Reading stored codes and component test - KeepRite (F/G)9MXE KeepRite · Furnace
- Reading stored codes and component test - KeepRite (F/G)9MXT KeepRite · Furnace
Source: KeepRite/ICP (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, Fig. 16 troubleshooting flow chart, p.24-25; KeepRite/ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Fig. 16, p.24-25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.