Updated · by Aurora Star Tech Inc.

Cascade unit power and transmission conduit entry on a Daikin water heater: Power and ground enter through a 1-3/8 in (34.5 mm) hole. Transmission to the tank control board and three-way valve circuit uses its own knockout.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Mega-Q cascade unit

How to fix cascade unit power and transmission conduit entry: step by step

  1. Remove the resin wall hole cover by squeezing its top and bottom and pulling it out.
  2. Open the knockout with a hammer or similar tool.
  3. Remove burrs and paint the opening with repair paint to prevent rust.
  4. Protect wiring passing the knockout with protective tape.
  5. Seal gaps with putty or similar material if small animals could enter the unit.
  6. Install the conduit with the mounting plate and a field-supplied lock nut.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Water Heater codes

Source: Daikin Mega-Q installation manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.