Rinnai Error Code 01: Control mode setting 01 (remote thermostat mode) (Wall Furnace)
Rinnai error code 01 on a wall furnace means: Control mode setting 01 (remote thermostat mode). It is also called Rinnai diagnostic code 01.
Homeowner? What Rinnai code 01 means for you
Usually minor Your wall furnace is reporting: Control mode setting 01 (remote thermostat mode). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 01 mean?
Selects remote thermostat mode, for when a wall thermostat kit is installed. Do not select it without the thermostat connection parts installed. The remote thermostat does not turn the furnace on or off, ON/OFF must still be used. Fault codes show on the furnace display, not on the remote thermostat. Unplugging the furnace within two hours of entering this mode sends it back to the factory default.
Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
Rinnai models that use code 01
EX08DTEX11DTEX17DTEX22DTEX22DT-W
Other Rinnai Wall Furnace codes
All Rinnai Wall Furnace error codes →
Rinnai code 01: homeowner questions
What does Rinnai code 01 mean?
Control mode setting 01 (remote thermostat mode). Selects remote thermostat mode, for when a wall thermostat kit is installed. Do not select it without the thermostat connection parts installed. The remote thermostat does not turn the furnace on or off, ON/OFF must still be used. Fault…
Is it safe to keep using my wall furnace with code 01?
Usually yes. Code 01 is normally minor, but if it keeps coming back have it checked.
Can I reset Rinnai code 01 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 01 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 01 near me?
Aurora Star Tech Inc. repairs Rinnai wall furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check
Troubleshooting guides
- Lock or unlock the control panel Rinnai · Wall Furnace
- Select remote thermostat mode (01) or control panel mode (02) Rinnai · Wall Furnace
- Select the gas code (gas type, altitude, vent length) Rinnai · Wall Furnace
- Set low and high fire gas pressure with the Test Switch Rinnai · Wall Furnace
- Switch the display between Fahrenheit and Celsius Rinnai · Wall Furnace
- Turn Set back (frost protection) on or off Rinnai · Wall Furnace
Source: Rinnai EX08DT/EX11DT Installation and Operation Manual (200000083) and EX17DT/EX22DT (200000084), Remote thermostat p.32-33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.