Gree Error Code n1: Defrost cycle K1 setting (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code n1 on a heat pump means: Defrost cycle K1 setting. It is also called Gree diagnostic code n1.

Low severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code n1 means for you

Usually minor Your heat pump is reporting: Defrost cycle K1 setting. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code n1 mean?

n1 is the function code for the defrost cycle K1, which can be set to 40, 50 or 60 minutes. The manual refers to the wired controller manual for how it is set.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code n1

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
Light x6View stored malfunction code on remote
LJIndoor function DIP setting wrong
Lock iconRemote keypad locked
LPIndoor and outdoor units do not match
LUPG fan motor zero-crossing fault
n0Auto energy saving (menu)
n3Forced defrost (menu)
n4Maximum output limit (forced energy saving)
n5Indoor engineering number offset
n6Fault history query
n7Running parameter query
n8Indoor engineering number query

All Gree Heat Pump error codes →

Gree code n1: homeowner questions

What does Gree code n1 mean?

Defrost cycle K1 setting. n1 is the function code for the defrost cycle K1, which can be set to 40, 50 or 60 minutes. The manual refers to the wired controller manual for how it is set.

Is it safe to keep using my heat pump with code n1?

Usually yes. Code n1 is normally minor, but if it keeps coming back have it checked.

Can I reset Gree code n1 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code n1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code n1 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.