Carrier 25VNA837 Error Codes
Carrier 25VNA837 error codes and diagnostic codes. The 25VNA837 is a Carrier heat pump in the Carrier Infinity 18VS 25VNA8 series.
Carrier 25VNA837 error codes list
Troubleshooting the 25VNA837
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Outdoor coil airflow clearance All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Amber STATUS or green COMM light not on Carrier · Heat Pump
- Delay before the compressor restarts Carrier · Heat Pump
- Heat pump will not defrost - HK32EA defrost board Carrier · Heat Pump
- Noisy compressor or loud defrost shift - Carrier split systems Carrier · Heat Pump
- Outdoor ECM fan not running - Carrier 25HNB9/24ANB1 Carrier · Heat Pump
- Outdoor unit unresponsive after several faults Carrier · Heat Pump
- Outdoor unit will not run - HK32EA defrost board heat pumps Carrier · Heat Pump
- Recall the active status code on the outdoor board (25VNA8/24VNA9) Carrier · Heat Pump
- Refrigerant charging mode on Infinity control (25VNA8/24VNA9) Carrier · Heat Pump
All Carrier Heat Pump error codes →
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.