Lennox Error Code 4 flashes: Low flame signal (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code 4 flashes on a furnace means: Low flame signal. It is also called Lennox diagnostic code 4 flashes.

Medium severityFurnaceLennox EL195UHNE

Homeowner? What Lennox code 4 flashes means for you

Check, then call Your furnace is reporting: Low flame signal. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 4 flashes mean?

Flame signal is weak. The control keeps running but warns that the flame sensor needs attention.

Applies to: EL195UHNE furnaces with ignition control 103217-03 or 107163-01 (red LED)

Common causes of Lennox code 4 flashes

  • Oxidized or dirty flame sensor
  • Sensor bent away from flame
  • Poor ground

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 4 flashes

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

Other Lennox Furnace codes

CodeMeaning
--Double dashes - zone sensor problem
1 flashLine voltage polarity reversed
2 flashesImproper earth ground
3 flashesBurner failed to light or lost flame
5 flashesWatchguard - ignition retries/recycles exceeded
7 flashesPrimary or secondary limit open
8 flashesRollout switch open
9 flashesPressure switch stays open or drops out on a heat call
10Unknown device detected
10 flashesWatchguard - pressure switch opened 5 times in one heat demand
11Missing device
11 flashesPressure switch stuck closed before inducer starts

All Lennox Furnace error codes →

Lennox code 4 flashes: homeowner questions

What does Lennox code 4 flashes mean?

Low flame signal. Flame signal is weak. The control keeps running but warns that the flame sensor needs attention.

Is it safe to keep using my furnace with code 4 flashes?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code 4 flashes myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 4 flashes comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 4 flashes near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), Table 4 (103217-03) / Table 5 (107163-01) diagnostic codes, p.8-10; Table 7, p.12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977