Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Midea BGH96M080C4A Error Codes

Updated · by Aurora Star Tech Inc.

Midea BGH96M080C4A error codes and diagnostic codes. The BGH96M080C4A is a Midea furnace in the Midea 96% AFUE A2L Gas Furnace (BGH96M) series.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Midea BGH96M080C4A error codes list

CodeMeaningSeverity
E1Low-fire pressure switch stuck closedHigh
E2Low pressure switch stuck openHigh
E3High pressure switch stuck openHigh
E4Pressure switch cycle lockoutHigh
E5Limit/rollout switch open less than 5 minutesHigh
E6Limit/rollout switch open more than 5 minutesCritical
E7System lockout - failed ignitionHigh
E8System lockout - too many flame dropoutsHigh
FLLow flame signalMedium
LED2 green 1 flashRefrigerant leak sensor communication failureHigh
LED2 green 2 flashesRefrigerant concentration above alarm limit (leak)Critical
LED2 green 3 flashesSensor connected but SW1-2 OFF (DIP reminder)Low
LED2 green 4 flashesRefrigerant sensor expired or faultyHigh
PrIncorrect polarity of L1/L2Medium

Troubleshooting the BGH96M080C4A

All Midea Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.