Midea Error Code E5: Limit/rollout switch open less than 5 minutes (Furnace)

Updated · by Aurora Star Tech Inc.

Midea error code E5 on a furnace means: Limit/rollout switch open less than 5 minutes. It is also called Midea diagnostic code E5.

High severityFurnaceMidea 96% AFUE A2L Gas Furnace (BGH96M)

Homeowner? What Midea code E5 means for you

Call a technician Your furnace is reporting: Limit/rollout switch open less than 5 minutes. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code E5 mean?

A high-limit or flame-rollout switch opened and re-closed within 5 minutes. Usually overheating from poor airflow; a rollout trip can mean a venting/combustion problem.

Applies to: Midea BGH96M 96% AFUE two-stage gas furnaces (060B3A, 080B3A, 080C4A, 100C5A, 100D5A, 120D5A)

Common causes of Midea code E5

  • Dirty filter or restricted ductwork
  • Blower not starting or wrong speed tap
  • Blower motor fault

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code E5

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Other Midea Furnace codes

CodeMeaning
E1Low-fire pressure switch stuck closed
E2Low pressure switch stuck open
E3High pressure switch stuck open
E4Pressure switch cycle lockout
E6Limit/rollout switch open more than 5 minutes
E7System lockout - failed ignition
E8System lockout - too many flame dropouts
FLLow flame signal
LED2 green 1 flashRefrigerant leak sensor communication failure
LED2 green 2 flashesRefrigerant concentration above alarm limit (leak)
LED2 green 3 flashesSensor connected but SW1-2 OFF (DIP reminder)
LED2 green 4 flashesRefrigerant sensor expired or faulty

All Midea Furnace error codes →

Midea code E5: homeowner questions

What does Midea code E5 mean?

Limit/rollout switch open less than 5 minutes. A high-limit or flame-rollout switch opened and re-closed within 5 minutes. Usually overheating from poor airflow; a rollout trip can mean a venting/combustion problem.

Is it safe to keep using my furnace with code E5?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Midea code E5 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code E5 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code E5 near me?

Aurora Star Tech Inc. repairs Midea furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Midea 96% AFUE Gas Furnace (A2L) Troubleshooting Guide, Section 3.5 E5/E6 chart, Figs. 19-22, Tables 3-5, p.16-19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.