Midea Error Code FL: Low flame signal (Furnace)

Updated · by Aurora Star Tech Inc.

Midea error code FL on a furnace means: Low flame signal. It is also called Midea diagnostic code FL.

Medium severityFurnaceMidea 96% AFUE A2L Gas Furnace (BGH96M)

Homeowner? What Midea code FL means for you

Check, then call Your furnace is reporting: Low flame signal. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code FL mean?

The control is seeing a weak flame signal. The furnace may still run but is at risk of flame dropouts (E8).

Applies to: Midea BGH96M 96% AFUE two-stage gas furnaces (060B3A, 080B3A, 080C4A, 100C5A, 100D5A, 120D5A)

Common causes of Midea code FL

  • Dirty or broken flame sensor
  • Poor control board ground
  • Manifold or inlet gas pressure out of range

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code FL

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Other Midea Furnace codes

CodeMeaning
E3High pressure switch stuck open
E4Pressure switch cycle lockout
E5Limit/rollout switch open less than 5 minutes
E6Limit/rollout switch open more than 5 minutes
E7System lockout - failed ignition
E8System lockout - too many flame dropouts
LED2 green 1 flashRefrigerant leak sensor communication failure
LED2 green 2 flashesRefrigerant concentration above alarm limit (leak)
LED2 green 3 flashesSensor connected but SW1-2 OFF (DIP reminder)
LED2 green 4 flashesRefrigerant sensor expired or faulty
PrIncorrect polarity of L1/L2

All Midea Furnace error codes →

Midea code FL: homeowner questions

What does Midea code FL mean?

Low flame signal. The control is seeing a weak flame signal. The furnace may still run but is at risk of flame dropouts (E8).

Is it safe to keep using my furnace with code FL?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code FL myself?

You can try one reset (power off for 30 seconds, then on). If Midea code FL comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code FL near me?

Aurora Star Tech Inc. repairs Midea furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Midea 96% AFUE Gas Furnace (A2L) Troubleshooting Guide, Section 3.7 FL chart, Tables 1-2, Fig. 12, p.21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.