Midea Error Code E6: Limit/rollout switch open more than 5 minutes (Furnace)

Updated · by Aurora Star Tech Inc.

Midea error code E6 on a furnace means: Limit/rollout switch open more than 5 minutes. It is also called Midea diagnostic code E6.

Critical severityFurnaceMidea 96% AFUE A2L Gas Furnace (BGH96M)

Homeowner? What Midea code E6 means for you

Stop and call Your furnace is reporting: Limit/rollout switch open more than 5 minutes. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code E6 mean?

A high-limit or flame-rollout switch has stayed open for over 5 minutes. A rollout switch is manual reset and will stay open until its button is pressed.

Applies to: Midea BGH96M 96% AFUE two-stage gas furnaces (060B3A, 080B3A, 080C4A, 100C5A, 100D5A, 120D5A)

Common causes of Midea code E6

  • Tripped manual-reset rollout switch
  • Severe airflow restriction or blower failure
  • Failed limit switch (open)

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code E6

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Other Midea Furnace codes

CodeMeaning
E1Low-fire pressure switch stuck closed
E2Low pressure switch stuck open
E3High pressure switch stuck open
E4Pressure switch cycle lockout
E5Limit/rollout switch open less than 5 minutes
E7System lockout - failed ignition
E8System lockout - too many flame dropouts
FLLow flame signal
LED2 green 1 flashRefrigerant leak sensor communication failure
LED2 green 2 flashesRefrigerant concentration above alarm limit (leak)
LED2 green 3 flashesSensor connected but SW1-2 OFF (DIP reminder)
LED2 green 4 flashesRefrigerant sensor expired or faulty

All Midea Furnace error codes →

Midea code E6: homeowner questions

What does Midea code E6 mean?

Limit/rollout switch open more than 5 minutes. A high-limit or flame-rollout switch has stayed open for over 5 minutes. A rollout switch is manual reset and will stay open until its button is pressed.

Is it safe to keep using my furnace with code E6?

No. Code E6 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Midea code E6 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Midea code E6 near me?

Aurora Star Tech Inc. repairs Midea furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Midea 96% AFUE Gas Furnace (A2L) Troubleshooting Guide, Section 3.5 E5/E6 chart, Figs. 19-22, Tables 3-5, p.16-19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.