Rinnai Error Code 73: Burner thermocouple fault (Tankless)
Rinnai error code 73 on a tankless water heater means: Burner thermocouple fault. It is also called Rinnai diagnostic code 73.
Homeowner? What Rinnai code 73 means for you
Call a technician Your tankless water heater is reporting: Burner thermocouple fault. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
- Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the hot and cold water valves under the heater are fully open.
- If you have a remote controller, turn it off and on once. If the code comes back, call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 73 mean?
Fault in the burner thermocouple circuit on Non-SENSEI units, which may stem from wiring, altitude DIP settings, manifold gas pressures, the thermocouple itself or the board.
Applies to: Non-SENSEI Series
Common causes of Rinnai code 73
- Loose, broken or damaged thermocouple wiring
- DIP switches not set for the installation altitude
- Low/high fire manifold gas pressures off factory spec
A technician checks these and 2 other possible causes on site before replacing any part.
Rinnai models that use code 73
Show all 67 models
C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94eV94iV94XiVE140eVE140iVE160eVE160iVE180eVE180iVE199eVE199i
Other Rinnai Tankless codes
All Rinnai Tankless Water Heater error codes →
Rinnai code 73: homeowner questions
What does Rinnai code 73 mean?
Burner thermocouple fault. Fault in the burner thermocouple circuit on Non-SENSEI units, which may stem from wiring, altitude DIP settings, manifold gas pressures, the thermocouple itself or the board.
Is it safe to keep using my tankless water heater with code 73?
It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rinnai code 73 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 73 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 73 near me?
Aurora Star Tech Inc. repairs Rinnai tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check
Troubleshooting guides
- No hot water All brands · Tankless Water Heater
- Water temperature fluctuates All brands · Tankless Water Heater
- Alternate piping arrangements Rinnai · Tankless Water Heater
- Balance hot water risers after install Rinnai · Tankless Water Heater
- BMS Gateway: building system cannot talk to the gateway Rinnai · Tankless Water Heater
- BMS Gateway: cannot log in to the setup screens Rinnai · Tankless Water Heater
- BMS Gateway: gateway cannot see the tankless heaters Rinnai · Tankless Water Heater
- BMS Gateway: reset IP address and admin password to default Rinnai · Tankless Water Heater
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.61. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.