Navien Error Code E598: RTC communication abnormality (Boiler)
Navien error code E598 on a boiler means: RTC communication abnormality. It is also called Navien diagnostic code E598.
Homeowner? What Navien code E598 means for you
Call a technician Your boiler is reporting: RTC communication abnormality. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code E598 mean?
The real-time clock is not communicating correctly.
Applies to: NCB700 condensing combi-boiler
Other Navien Boiler codes
All Navien Boiler error codes →
Navien code E598: homeowner questions
What does Navien code E598 mean?
RTC communication abnormality. The real-time clock is not communicating correctly.
Is it safe to keep using my boiler with code E598?
It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Navien code E598 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code E598 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code E598 near me?
Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
Source: Navien NCB700 installation and operation manual, p. 137. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.