Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code 52: Repeated compressor faults (minor) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code 52 on a heat pump means: Repeated compressor faults (minor). It is also called Daikin diagnostic code 52.

Medium severityHeat PumpDaikin FIT DH6VS/DH7VSA

Homeowner? What Daikin code 52 means for you

Check, then call Your heat pump is reporting: Repeated compressor faults (minor). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code 52 mean?

The thermostat shows 52; the board shows nothing. Several compressor faults, but the control lets the unit keep running.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code 52

  • Stop valve not fully open
  • Lost phase on the compressor wires
  • Compressor motor failure
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code 52

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other Daikin Heat Pump codes

CodeMeaning
14Repeated high pressure faults (minor)
16Repeated low pressure faults (minor)
33Outdoor control board overheating (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
CoreSense 1CoreSense: yellow 1 flash, long run time
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)

All Daikin Heat Pump error codes →

Daikin code 52: homeowner questions

What does Daikin code 52 mean?

Repeated compressor faults (minor). The thermostat shows 52; the board shows nothing. Several compressor faults, but the control lets the unit keep running.

Is it safe to keep using my heat pump with code 52?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code 52 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code 52 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code 52 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.45 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977