Viessmann 704092 Error Codes
Viessmann 704092 error codes and diagnostic codes (also listed as with BACnet IP). The 704092 is a Viessmann boiler in the Versatronik 300 Cascade Control series.
Viessmann 704092 error codes list
| Code | Meaning | Severity |
|---|---|---|
| A | AUX demand active indicator | Low |
| C4 | 0-10 V module communication failure | Medium |
| d2 | Fault module 2 communication failure | Medium |
| d3 | EA1 module communication failure | Medium |
| E1 | Gas valve 1 / gas pressure monitoring 1 fault | Critical |
| E2 | Gas valve 2 / gas pressure monitoring 2 fault | Critical |
| E3 | Safety chain error | Critical |
| EC | Safety relay fault | Critical |
| ED | Ignition relay fault | Critical |
| EE | Internal feedback error, gas safety valves | Critical |
| EF | Internal feedback error, gas safety valves | Critical |
Troubleshooting the 704092
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
- Won't fire All brands · Boiler
- Acknowledged fault comes back Viessmann · Boiler
- AUX 0-10 VDC input wiring Viessmann · Boiler
- AUX heat demand input wiring Viessmann · Boiler
- Boiler does not fire although the control calls for heat Viessmann · Boiler
- Change AUX input mode to 0-10 VDC Viessmann · Boiler
- Condensate not draining, burner shuts down Viessmann · Boiler
- Connecting Vitodens 200 WB2B with Vitotronic 200 HO1 to the Versatronik 300 Viessmann · Boiler
- Connecting Vitodens B2HA with black GUI to the Versatronik 300 Viessmann · Boiler
- Enable the INT interlock in Specifications Viessmann · Boiler
- Fault codes are shown in hexadecimal Viessmann · Boiler
- Fitting the LON end-of-line resistor Viessmann · Boiler
- INT boiler disable interlock wiring Viessmann · Boiler
- Intended use Viessmann · Boiler
- Lag boilers lose contact with lead boiler (cascade) Viessmann · Boiler
- Mounting the Versatronik 300 control Viessmann · Boiler
- Outdoor sensor fault appears on Vitodens if sensor is missing Viessmann · Boiler
- Outdoor temperature sensor location Viessmann · Boiler
- Outdoor temperature sensor wiring Viessmann · Boiler
- Set BACnet device ID and IP before joining the network Viessmann · Boiler
- Set the AUX demand set point (DMD SetP) Viessmann · Boiler
- Set Vitodens WB2B coding 00 to 00 Viessmann · Boiler
- Supply and return temperature sensor installation Viessmann · Boiler
- Vitodens 200 WB2B with Vitotronic 100 HC1 communication wiring Viessmann · Boiler
- Vitodens 200 WB2B with Vitotronic 200 HO1 communication wiring and outdoor sensor Viessmann · Boiler
- Vitotronic 100 GC1 / GC1B communication wiring Viessmann · Boiler
- Vitotronic 300 GW5B communication wiring Viessmann · Boiler
All Viessmann Boiler error codes →
Homeowner help: Boiler Not Heating: What to Check
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.