Weil-McLain Error Code Pb: Anti-freeze mode (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code Pb on a heat pump means: Anti-freeze mode. It is also called Weil-McLain diagnostic code Pb.

Low severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code Pb means for you

Usually minor Your heat pump is reporting: Anti-freeze mode. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code Pb mean?

Status, not a fault. The unit is running its freeze protection.

Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)

Common causes of Weil-McLain code Pb

  • Water temperature low enough to start freeze protection
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code Pb

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
P0Low pressure protection
P1High pressure protection
P3AC current protection
P4Compressor discharge temperature too high
P5Water temperature difference too high (Tw_out - Tw_in)
P6Inverter module protection
PdOutdoor coil (T3) temperature too high
PPTw_out - Tw_in reading not normal

All Weil-McLain Heat Pump error codes →

Weil-McLain code Pb: homeowner questions

What does Weil-McLain code Pb mean?

Anti-freeze mode. Status, not a fault. The unit is running its freeze protection.

Is it safe to keep using my heat pump with code Pb?

Usually yes. Code Pb is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code Pb myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code Pb comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code Pb near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.3 Error codes, p.56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977