Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code H4: L0/L1 protection happened 3 times in an hour (Heat Pump)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code H4 on a heat pump means: L0/L1 protection happened 3 times in an hour. It is also called Weil-McLain diagnostic code H4.

High severityHeat PumpWeil-McLain ECO HP

Homeowner? What Weil-McLain code H4 means for you

Call a technician Your heat pump is reporting: L0/L1 protection happened 3 times in an hour. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code H4 mean?

The unit shows H4 when L0 and L1 trips add up to three within one hour.

Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)

Common causes of Weil-McLain code H4

  • Same as L0 and L1 (inverter module fault / DC bus low voltage)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Weil-McLain models that use code H4

ECO HP 41ECO HP 48ECO HP 55

Other Weil-McLain Heat Pump codes

CodeMeaning
ELCommunication fault between hydraulic module and MH-kit
F1DC bus low voltage
H0Communication fault between indoor and outdoor unit
H1Communication fault between main board and inverter board (outdoor)
H2Refrigerant temperature sensor at plate HX outlet (heating) (T2) fault
H3Refrigerant temperature sensor at plate HX inlet (heating) (T2B) fault
H5Room temperature sensor (Ta) fault
H6DC fan motor fault
H7AC supply voltage protection
H8Pressure sensor fault
H9Zone 2 water temperature sensor (Tw2) fault
HAWater outlet temperature sensor (Tw_out) fault

All Weil-McLain Heat Pump error codes →

Weil-McLain code H4: homeowner questions

What does Weil-McLain code H4 mean?

L0/L1 protection happened 3 times in an hour. The unit shows H4 when L0 and L1 trips add up to three within one hour.

Is it safe to keep using my heat pump with code H4?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code H4 myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code H4 comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code H4 near me?

Aurora Star Tech Inc. repairs Weil-McLain heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service