Rheem furnace: Heating ignition and blower sequence
This page follows a heating cycle for a Rheem 96V two-stage furnace, including the blower start and what happens if the burners do not light.
How the Rheem furnace works: Heating ignition and blower sequence
What this is. This page follows a heating cycle for a Rheem 96V two-stage furnace, including the blower start and what happens if the burners do not light.
What happens, in order. When the thermostat calls for heat, the inducer starts on low speed for a 30-second pre-purge. The igniter then sparks and the gas valve is energized for each ignition trial, for about 7 seconds. The furnace makes up to four attempts. Once the burners are lit, the blower starts on high heat roughly 15 to 20 seconds later. The furnace stays on low fire until the thermostat is satisfied or the call ends. Then the inducer runs a post-purge and shuts off after about 90 seconds.
If it does not light. After four failed attempts, the furnace locks out for one hour and then tries again by itself.
Fault codes. The control lists codes such as 11, 12, 13, 22, 33, 45, 46, 57 and H. For the pressure-related ones, 45, 46 and 57, the inducer runs for 60 seconds, then switches off for 5 minutes before retrying. A technician uses these codes to find the cause, so note whichever you see.
What is normal. A pause before the flame, clicking, the blower arriving after the burners light, and fans running on after the flame goes out.
Safe checks. Replace the filter, open the registers, clear outside vent pipes of snow, and check the thermostat and breaker.
When to call a technician. Any repeated code or lockout. Aurora Star Tech can help; if you smell gas, leave and call from outside.
Key times at a glance
| What | How long or how much |
|---|---|
| Inducer pre-purge at low speed | 30 seconds |
| Gas valve voltage per ignition trial | 7 seconds |
| Ignition attempts before lockout | 4 attempts |
| Lockout after failed attempts | 1 hour |
| ECM blower start on high heat after burner light | 15-20 seconds |
| Inducer post purge after heat call ends | 90 seconds plus slew |
| Inducer run before fault shutoff (codes 45, 46, 57) | 60 seconds, then off 5 minutes |
Applies to: 96V and 96MDV series 2-stage communicating furnaces
Error codes linked to this step
Rheem code 11Rheem code 13Rheem code 12Rheem code 22Rheem code 33Rheem code 45Rheem code 46Rheem code 57Rheem code H
Questions about the Rheem furnace
What is the Heating ignition and blower sequence on a Rheem furnace?
This page follows a heating cycle for a Rheem 96V two-stage furnace, including the blower start and what happens if the burners do not light.
Is it normal for my Rheem furnace to do this?
A pause before the flame, clicking, the blower arriving after the burners light, and fans running on after the flame goes out.
Who can service my Rheem furnace near me?
Aurora Star Tech Inc. repairs and services Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.