Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman GCES96 Error Codes

Updated · by Aurora Star Tech Inc.

Goodman GCES96 error codes and diagnostic codes (also listed as *CES96, Goodman 96% downflow/horizontal). The GCES96 is a Goodman furnace in the Goodman/Amana *MES9 single-stage series.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Goodman GCES96 error codes list

CodeMeaningSeverity
1 flashLockout - three failed ignition triesHigh
2 flashesPressure switch stuck closedHigh
3 flashesPressure switch stuck openHigh
4 flashesPrimary or auxiliary limit openHigh
5 flashesFlame sensed with no call for heatCritical
6 flashesRollout limit open or control fuse blownHigh
7 flashesLow flame signalMedium
8 flashesIgniter relay faultHigh
9 flashesTwinning faultMedium
10 flashesOpen fuse - no 24 V at the controlMedium
11 flashesIgniter openHigh
12 flashesInducer relay faultHigh
LED offNo LED - no power or control failureHigh
LED steady onNormal operationLow
Rapid flashReversed polarityHigh

Troubleshooting the GCES96

All Goodman Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977