Rheem Error Code F: Continuous fan on (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code F on a furnace means: Continuous fan on. It is also called Rheem diagnostic code F.

Low severityFurnaceRheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC) · R95P · R96V/96MDV

Homeowner? What Rheem code F means for you

Usually minor Your furnace is reporting: Continuous fan on. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code F mean?

F on the display means the blower is running continuously from a fan-only call (thermostat fan switch on). Normal. A lockout fault code replaces the F while the control is locked out.

Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code F

Show all 23 models

96MDV040B30A96MDV060B30A96MDV070B30A96MDV085C50A96MDV100C50A96MDV115D50AR95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR96VA0401317MSAR96VA0601317MSAR96VA0701317MSAR96VA0851521MSAR96VA1001521MSAR96VA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA

Other Rheem Furnace codes

CodeMeaning
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)
dFDefrost in progress (dual fuel)
FAULT HISTORY menuFurnace user menu - FAULT HISTORY
Fault recallPower-up replay of the last three faults
Fault recall - last 5Power-up replay of the last five faults
FIXED FIRE RATEForced low or high fire test (SETUP menu)
FLFault history (pushbutton status menu)
Flame LED offNo flame sensed (troubleshooting aid)

All Rheem Furnace error codes →

Rheem code F: homeowner questions

What does Rheem code F mean?

Continuous fan on. F on the display means the blower is running continuously from a fan-only call (thermostat fan switch on). Normal. A lockout fault code replaces the F while the control is locked out.

Is it safe to keep using my furnace with code F?

Usually yes. Code F is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code F myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code F comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code F near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Rheem (-)802PA Installation Instructions, Diagnostics and Fault Codes (UT 1028-928 control), pp.40-41; R95P pp.87-89. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.