KeepRite Error Code Component self-test: Run all furnace components for a short test (Furnace)
KeepRite error code Component self-test on a furnace means: Run all furnace components for a short test. It is also called KeepRite diagnostic code Component self-test.
Homeowner? What KeepRite code Component self-test means for you
Usually minor Your furnace is reporting: Run all furnace components for a short test. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does KeepRite error code Component self-test mean?
Runs the inducer, igniter and blower speeds for a short time so you can see each part work. The gas valve and the humidifier terminal are not energized. It will not start with any thermostat signal present or while time delays are running. Holding the jumper longer than 2 seconds makes the LED flash code 10 and the request is ignored.
Applies to: (F/G)9MXE and (F/G)9MXT furnaces
KeepRite models that use code Component self-test
G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422A
Other KeepRite Furnace codes
All KeepRite Furnace error codes →
KeepRite code Component self-test: homeowner questions
What does KeepRite code Component self-test mean?
Run all furnace components for a short test. Runs the inducer, igniter and blower speeds for a short time so you can see each part work. The gas valve and the humidifier terminal are not energized. It will not start with any thermostat signal present or while time delays are…
Is it safe to keep using my furnace with code Component self-test?
Usually yes. Code Component self-test is normally minor, but if it keeps coming back have it checked.
Can I reset KeepRite code Component self-test myself?
You can try one reset (power off for 30 seconds, then on). If KeepRite code Component self-test comes back, the cause is still there and a licensed technician should check it.
Who can fix KeepRite code Component self-test near me?
Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: KeepRite ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Component Self-Test, p.14-15; (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, p.14-15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.