Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

KeepRite Error Code LED heartbeat: Control OK – idle or running, no faults (Furnace)

Updated · by Aurora Star Tech Inc.

KeepRite error code LED heartbeat on a furnace means: Control OK - idle or running, no faults. It is also called KeepRite diagnostic code LED heartbeat.

Low severityFurnaceKeepRite (F/G)9MXE Single-Stage Furnace · KeepRite (F/G)9MXT Two-Stage Furnace

Homeowner? What KeepRite code LED heartbeat means for you

Usually minor Your furnace is reporting: Control OK - idle or running, no faults. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code LED heartbeat mean?

The green status LED on the furnace control pulses (bright-dim heartbeat) when the control is powered and has no active fault. Right after a power interruption during a heat call the LED flashes code 1+2 during the blower run period, then returns to the heartbeat.

Applies to: (F/G)9MXE and (F/G)9MXT furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code LED heartbeat

G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422A

Other KeepRite Furnace codes

CodeMeaning
6+1Ignition lockout after 4 failed tries
7Limit circuit lockout
8Gas heating lockout - manual reset needed
9High-heat pressure switch or relay did not close or reopened
10Line voltage polarity reversed
Component self-testRun all furnace components for a short test
LED offStatus LED dark - no power to the control or blown 3 A fuse
LED steady ONStatus LED on solid - control lockout (resets after 1 hour)
Stored fault recallRead the last stored fault code from the control

All KeepRite Furnace error codes →

KeepRite code LED heartbeat: homeowner questions

What does KeepRite code LED heartbeat mean?

Control OK - idle or running, no faults. The green status LED on the furnace control pulses (bright-dim heartbeat) when the control is powered and has no active fault. Right after a power interruption during a heat call the LED flashes code 1+2 during the blower run period, then…

Is it safe to keep using my furnace with code LED heartbeat?

Usually yes. Code LED heartbeat is normally minor, but if it keeps coming back have it checked.

Can I reset KeepRite code LED heartbeat myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code LED heartbeat comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code LED heartbeat near me?

Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: KeepRite ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Service and Technical Support, Furnace Control Diagnostics, p.14 and Sequence of Operation, p.26; (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, p.14 and p.25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977