Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Gree Error Code nA: System mode: cooling and heating (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code nA on a heat pump means: System mode: cooling and heating. It is also called Gree diagnostic code nA.

Low severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code nA means for you

Usually minor Your heat pump is reporting: System mode: cooling and heating. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code nA mean?

nA is the value of A6 that allows cooling, dry, heating and fan operation (heating cannot run together with the other modes). It is the factory default.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code nA

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
n4Maximum output limit (forced energy saving)
n5Indoor engineering number offset
n6Fault history query
n7Running parameter query
n8Indoor engineering number query
n9Online indoor unit count
nbOutdoor and controller barcode query
nCSystem mode: cooling only
nENegative number prefix
nFSystem mode: fan only
nHSystem mode: heating only
nJHigh temperature prevention when heating (factory function)

All Gree Heat Pump error codes →

Gree code nA: homeowner questions

What does Gree code nA mean?

System mode: cooling and heating. nA is the value of A6 that allows cooling, dry, heating and fan operation (heating cannot run together with the other modes). It is the factory default.

Is it safe to keep using my heat pump with code nA?

Usually yes. Code nA is normally minor, but if it keeps coming back have it checked.

Can I reset Gree code nA myself?

You can try one reset (power off for 30 seconds, then on). If Gree code nA comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code nA near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section 4.2.3.3 and Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service