Goodman Error Code gH2: Gas heat, high stage (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code gH2 on a furnace means: Gas heat, high stage. It is also called Goodman diagnostic code gH2.

Low severityFurnaceGoodman/Amana GM9C96/AM9C96

Homeowner? What Goodman code gH2 means for you

Usually minor Your furnace is reporting: Gas heat, high stage. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code gH2 mean?

Shown while the two-stage furnace is heating on high fire. Normal operation during a call for heat.

Applies to: GM9C96/AM9C96 two-stage furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code gH2

AC9C96AM9C96AM9C960303ANGC9C96GM9C96GM9C960303AN

Other Goodman Furnace codes

CodeMeaning
EEnIgniter open
EOLOEM test mode
ErrActive alarm menu
FAnContinuous fan
gHGas heat, single stage
gH1Gas heat, low stage
IdLIdle - no call
L6FLast 6 faults (view and clear)
rFdReset to factory defaults

All Goodman Furnace error codes →

Goodman code gH2: homeowner questions

What does Goodman code gH2 mean?

Gas heat, high stage. Shown while the two-stage furnace is heating on high fire. Normal operation during a call for heat.

Is it safe to keep using my furnace with code gH2?

Usually yes. Code gH2 is normally minor, but if it keeps coming back have it checked.

Can I reset Goodman code gH2 myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code gH2 comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code gH2 near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: GM9C96 service RS6612020r1, 2 Stage Status Codes p.34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.