KeepRite Error Code LED off: Status LED dark – no power to the control or blown 3 A fuse (Furnace)
KeepRite error code LED off on a furnace means: Status LED dark - no power to the control or blown 3 A fuse. It is also called KeepRite diagnostic code LED off.
Homeowner? What KeepRite code LED off means for you
Call a technician Your furnace is reporting: Status LED dark - no power to the control or blown 3 A fuse. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does KeepRite error code LED off mean?
The green status light shows nothing at all, so the board is not getting 115 V or 24 V.
Applies to: KeepRite (F/G)9MXE single-stage and (F/G)9MXT two-stage 95% furnaces
Common causes of KeepRite code LED off
- Breaker off or open wiring from the panel
- Blower door switch open or failed
- Transformer not putting out 24 V
A technician checks these and 2 other possible causes on site before replacing any part.
KeepRite models that use code LED off
G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422A
Other KeepRite Furnace codes
All KeepRite Furnace error codes →
KeepRite code LED off: homeowner questions
What does KeepRite code LED off mean?
Status LED dark - no power to the control or blown 3 A fuse. The green status light shows nothing at all, so the board is not getting 115 V or 24 V.
Is it safe to keep using my furnace with code LED off?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset KeepRite code LED off myself?
You can try one reset (power off for 30 seconds, then on). If KeepRite code LED off comes back, the cause is still there and a licensed technician should check it.
Who can fix KeepRite code LED off near me?
Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: KeepRite/ICP (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, Fig. 16 troubleshooting flow chart, p.24-25; KeepRite/ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Fig. 16, p.24-25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.