KeepRite Error Code 10: Line voltage polarity reversed (Furnace)

Updated · by Aurora Star Tech Inc.

KeepRite error code 10 on a furnace means: Line voltage polarity reversed. It is also called KeepRite diagnostic code 10.

Medium severityFurnaceKeepRite (F/G)9MXE Single-Stage Furnace · KeepRite (F/G)9MXT Two-Stage Furnace · KeepRite (F/G)96VTN Two-Stage Variable-Speed Furnace

Homeowner? What KeepRite code 10 means for you

Check, then call Your furnace is reporting: Line voltage polarity reversed. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code 10 mean?

The control sees 115 V polarity reversed (or the furnace is not grounded) and will not heat. On 96VTN the light flashes rapidly.

Applies to: KeepRite (F/G)9MXE, (F/G)9MXT and (F/G)96VTN furnaces

Common causes of KeepRite code 10

  • Hot and neutral swapped
  • Poor or missing ground
  • Twinned units with 24 V transformers out of phase
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code 10

Show all 25 models

G9MXE0401410AG9MXE0401714AG9MXE0601412AG9MXE0601714AG9MXE0801716AG9MXE0802120AG9MXE1002120AG9MXE1202422AG9MXT0401410AG9MXT0401712AG9MXT0601412AG9MXT0601714AG9MXT0801716AG9MXT0802120AG9MXT1002120AG9MXT1202422AG96VTN0401410G96VTN0401712G96VTN0601412G96VTN0601714G96VTN0801716G96VTN0802120G96VTN1002120G96VTN1002122G96VTN1202422

Other KeepRite Furnace codes

CodeMeaning
5Flame sensed with gas valve off
6Flame not proved during ignition trial
6+1Ignition lockout after 4 failed tries
7Limit circuit lockout
8Gas heating lockout - manual reset needed
9High-heat pressure switch or relay did not close or reopened
Component self-testRun all furnace components for a short test
LED heartbeatControl OK - idle or running, no faults
LED offStatus LED dark - no power to the control or blown 3 A fuse
LED steady ONStatus LED on solid - control lockout (resets after 1 hour)
Stored fault recallRead the last stored fault code from the control

All KeepRite Furnace error codes →

KeepRite code 10: homeowner questions

What does KeepRite code 10 mean?

Line voltage polarity reversed. The control sees 115 V polarity reversed (or the furnace is not grounded) and will not heat. On 96VTN the light flashes rapidly.

Is it safe to keep using my furnace with code 10?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset KeepRite code 10 myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code 10 comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code 10 near me?

Aurora Star Tech Inc. repairs KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: KeepRite/ICP (F/G)9MXE Service and Technical Support Manual 440 04 4311 09, Fig. 16 troubleshooting flow chart, p.24-25; KeepRite/ICP (F/G)9MXT Service and Technical Support Manual 440 04 4321 10, Fig. 16, p.24-25; KeepRite_ICP_F_G_96VTN_KeepRite_G96VTN_Tempstar_Heil_Arcoaire_installation_440_01_4801_00.txt - section Start-up, Adjustment and Safety Check / 115-V Wiring. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977