Gree Error Code H8: Fan drive module overheated (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code H8 on a heat pump means: Fan drive module overheated. It is also called Gree diagnostic code H8.

High severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code H8 means for you

Call a technician Your heat pump is reporting: Fan drive module overheated. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code H8 mean?

Outdoor fan drive fault: fan drive module overheated.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Common causes of Gree code H8

  • Fan motor or wiring problem
  • Supply voltage problem
  • Fan drive / main board fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code H8

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
H1Defrost or oil return (status)
H3Compressor overload protection
H4System abnormal (overload)
H5IPM (inverter module) protection
H6Indoor fan motor not running / no feedback
H7Compressor lost synchronism
H9Inverter fan lost synchronism
HAFan drive memory chip fault
HCPFC protection
HEInverter fan phase loss
HFFan drive charging circuit fault
HHFan drive DC bus voltage too high

All Gree Heat Pump error codes →

Gree code H8: homeowner questions

What does Gree code H8 mean?

Fan drive module overheated. Outdoor fan drive fault: fan drive module overheated.

Is it safe to keep using my heat pump with code H8?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code H8 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code H8 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code H8 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.