Lennox Error Code E154: Refrigerant leak sensor #1 communication lost / wrong DIP setting (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E154 on a furnace means: Refrigerant leak sensor #1 communication lost / wrong DIP setting. It is also called Lennox diagnostic code E154.

High severityFurnaceLennox ML180UHE

Homeowner? What Lennox code E154 means for you

Call a technician Your furnace is reporting: Refrigerant leak sensor #1 communication lost / wrong DIP setting. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E154 mean?

The control cannot talk to refrigerant detection sensor #1, or the Low GWP DIP switches do not match the sensors fitted. The blower latches on for at least 5 minutes after communication returns.

Applies to: ML180UHEK (R-454B era) single-stage 80% furnaces with integrated control 107792-XX (ML180UH045/070/090/110/135, incl. low-NOx X models)

Common causes of Lennox code E154

  • Damaged or unplugged sensor #1 wiring harness or connector
  • Sensor #1 damaged or plug obstructed
  • LGWP DIP switches set wrong (e.g. Enable with no sensor fitted)

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E154

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Other Lennox Furnace codes

CodeMeaning
E130Configuration jumper missing
E131Corrupted control parameters
E132Device control software fault
E150A2L refrigerant leak alarm
E151A2L sensor fault
E152Refrigerant leak sensor #2 fault
E155Refrigerant leak sensor #2 communication lost
E160Refrigerant leak sensor #1 wrong type
E161Refrigerant leak sensor #2 wrong type
E163Furnace control board failure
E164Low GWP test mode active
E180Outdoor air temperature sensor failure

All Lennox Furnace error codes →

Lennox code E154: homeowner questions

What does Lennox code E154 mean?

Refrigerant leak sensor #1 communication lost / wrong DIP setting. The control cannot talk to refrigerant detection sensor #1, or the Low GWP DIP switches do not match the sensors fitted. The blower latches on for at least 5 minutes after communication returns.

Is it safe to keep using my furnace with code E154?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E154 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E154 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E154 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox ML180UHEK Unit Information 100161/100166, Table 6 Integrated Diagnostic Codes, p.14; Table 17 LGWP DIP switch settings, p.33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.