Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code E39: Control board may need replacing (thermistor input) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code E39 on a heat pump means: Control board may need replacing (thermistor input). It is also called Daikin diagnostic code E39.

High severityHeat PumpDaikin FIT DH6VS/DH7VSA

Homeowner? What Daikin code E39 means for you

Call a technician Your heat pump is reporting: Control board may need replacing (thermistor input). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code E39 mean?

Thermostat shows 39, outdoor board display shows E39. The control flags a board problem; the manual points at the thermistor connections first.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code E39

  • Thermistor bad or not plugged in right
  • Bad control board
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code E39

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other Daikin Heat Pump codes

CodeMeaning
E32Outdoor control board overheating (critical)
E34High current detected
E35High current, possible short circuit
E36Abnormal start-up
E37Control board may need replacing (fan motor link)
E38Compressor voltage problem
E40Compressor setup does not match the unit
E41Low refrigerant
E42Low supply voltage
E43High supply voltage
E44Outdoor temperature out of operating range
E47System verification test blocked by indoor heat

All Daikin Heat Pump error codes →

Daikin code E39: homeowner questions

What does Daikin code E39 mean?

Control board may need replacing (thermistor input). Thermostat shows 39, outdoor board display shows E39. The control flags a board problem; the manual points at the thermistor connections first.

Is it safe to keep using my heat pump with code E39?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code E39 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code E39 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code E39 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977