Daikin Error Code CoreSense 1: CoreSense: yellow 1 flash, long run time (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code CoreSense 1 on a heat pump means: CoreSense: yellow 1 flash, long run time. It is also called Daikin diagnostic code CoreSense 1.

Medium severityHeat PumpDaikin R-32 DH4S/DH5S

Homeowner? What Daikin code CoreSense 1 means for you

Check, then call Your heat pump is reporting: CoreSense: yellow 1 flash, long run time. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code CoreSense 1 mean?

Yellow ALERT, 1 flash: the compressor has run more than 18 hours straight, which points to low capacity from a low side problem. No lockout. Code 1 is turned off in heat pump mode.

Applies to: DH4SQA, DH4SEA, DH5SEA (single stage R-32 heat pumps with CoreSense module)

Common causes of Daikin code CoreSense 1

  • Low charge
  • Indoor blower not running (relay, capacitor, motor, wiring, indoor board, open thermostat wire)
  • Frozen indoor coil (low suction, thermostat set very low, dirty filter or coil, blocked ducts or registers)

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code CoreSense 1

DH4SEA**10AADH4SQA**10AADH5SEA**10AA

Other Daikin Heat Pump codes

CodeMeaning
33Outdoor control board overheating (minor)
52Repeated compressor faults (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)
CoreSense 9CoreSense: red 9 flashes, PROT terminal over current
CoreSense solid redCoreSense: solid red TRIP

All Daikin Heat Pump error codes →

Daikin code CoreSense 1: homeowner questions

What does Daikin code CoreSense 1 mean?

CoreSense: yellow 1 flash, long run time. Yellow ALERT, 1 flash: the compressor has run more than 18 hours straight, which points to low capacity from a low side problem. No lockout. Code 1 is turned off in heat pump mode.

Is it safe to keep using my heat pump with code CoreSense 1?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code CoreSense 1 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code CoreSense 1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code CoreSense 1 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin RSD6200301 Service and Troubleshooting, DC3S/DC4S/DC5S AC and DH4S/DH5S heat pump R-32 (07-2024), Diagnostics Table: CoreSense Module p.20-21 and Table 1 Quick Reference p.22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.