Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code P3: Compressor drive overcurrent (Heat Pump)

Updated · by Aurora Star Tech Inc.

Navien error code P3 on a heat pump means: Compressor drive overcurrent. It is also called Navien diagnostic code P3.

High severityHeat PumpNavien NAZ

Homeowner? What Navien code P3 means for you

Call a technician Your heat pump is reporting: Compressor drive overcurrent. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code P3 mean?

The PCB measured too much running current. Trip points: 24K and 36K 26 A, 48K and 60K 32 A.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of Navien code P3

  • Loose compressor or fan motor wiring
  • Running far outside its range (hot-day cooling / cold-day heating)
  • Dirty or blocked outdoor coil, units too close, air short-cycling

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code P3

NAZ17V36NAZ17V60

Other Navien Heat Pump codes

CodeMeaning
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LECompressor speed held back by drive module temperature
LFCompressor speed held back by current
P1High pressure switch opened
P2Low pressure protection
P4Discharge temperature too high
P5Outdoor coil too hot in cooling
P6Compressor drive (IPM) module protection
P7Indoor coil freeze protection (T2)
P8Drive module (IPM) overheating
P9Outdoor fan motor fault

All Navien Heat Pump error codes →

Navien code P3: homeowner questions

What does Navien code P3 mean?

Compressor drive overcurrent. The PCB measured too much running current. Trip points: 24K and 36K 26 A, 48K and 60K 32 A.

Is it safe to keep using my heat pump with code P3?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code P3 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code P3 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code P3 near me?

Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.11, p.38-39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977