Goodman *MVC960803BNB* error codes list

CodeMeaningSeverity
ACCooling, single stageLow
AC1Cooling, low stage (communicating)Low
AC2Cooling, high stage (communicating)Low
AxxAirflow readoutLow
CFSComfort settingLow
dF1Defrost, low-stage gas heatLow
dF2Defrost, high-stage gas heatLow
dHLDehumidify logic input levelLow
dHUDehumidifier onLow
E12Redundant relay openHigh
E13Redundant relay stuck closedHigh
Eb0Blower motor not runningHigh
Eb1Lost communication with blower motorHigh
Eb2Blower motor hp does not match model dataMedium
Eb3Blower motor running in power, temperature or speed limitMedium
Eb4Blower motor current trip or lost rotor controlHigh
Eb5Blower motor locked rotorHigh
Eb6Blower motor over/under voltage or over temperatureHigh
Eb7Blower motor missing parametersHigh
Eb9Inadequate airflowMedium
Ec1Network communication alarmMedium
Ec2E-module network communication alarmMedium
Ec3Bluetooth module network communication alarmLow
Ed0No shared data on the networkMedium
Ed1Invalid data on networkMedium
Ed4Memory card data rejectedMedium
Ed5Invalid downloaded firmwareMedium
Ed6Unrecognized data IDMedium
EE7Igniter circuit fault or poor groundHigh
EEFCondensate switch openMedium
FSdConstant fan speedLow
gAFGas heat airflowLow
gbPBackup heat balance pointsLow
gFdGas heat fan off delayLow
gndGas heat fan on delayLow
gPtGas pressure testLow
gStGas heat stage multiplierLow
gtFGas heat trim factorLow
HEdHumidifier enableLow
HPHeat pump heat, single stageLow
HP1Heat pump heat, low stageLow
HP2Heat pump heat, high stageLow
HUdHumidifier onLow
LrnLearn menuLow
SH1Special heat relay 1Low
SH2Special heat relay 2Low
SrShared data revisionLow
uACInverter coolingLow
uHPInverter heat pump heatLow
utLVentilator onLow

Troubleshooting the *MVC960803BNB*

All Goodman Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.