Navien Error Code Boiler Pump Status: Input/Output Status item 5 – Boiler Pump Status (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code Boiler Pump Status on a boiler means: Input/Output Status item 5 - Boiler Pump Status. It is also called Navien diagnostic code Boiler Pump Status.

Low severityBoilerNavien NHB-H

Homeowner? What Navien code Boiler Pump Status means for you

Usually minor Your boiler is reporting: Input/Output Status item 5 - Boiler Pump Status. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code Boiler Pump Status mean?

Service menu 2. Input/Output Status, item 5: shows the state of the boiler pump output. Useful to see whether the control is seeing or sending a signal.

Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code Boiler Pump Status

NHB-055HNHB-080HNHB-110HNHB-150H

Other Navien Boiler codes

CodeMeaning
5~10th ignition - No. of TimesEMS Data counter 7
AHU connection iconAir handler connection
AHU SH Set TempStatus Information item 5 - AHU SH Set Temp
Air Handler Interface Output StatusInput/Output Status item 15 - Air Handler Interface Output Status
Approx. Boiler FlowStatus Information item 11 - Approx. Boiler Flow
Auto air purge iconAuto air purge running
Boost Interval TimeStatus Information item 23 - Boost Interval Time
Cascade/Main iconCascade main unit
Combustion iconBurner combusting
DHW/Zone1 Pump StatusInput/Output Status item 6 - DHW/Zone1 Pump Status
DHW demand iconDHW demand present
DHW Operation TimeService Status Info item 2 - DHW Operation Time

All Navien Boiler error codes →

Navien code Boiler Pump Status: homeowner questions

What does Navien code Boiler Pump Status mean?

Input/Output Status item 5 - Boiler Pump Status. Service menu 2. Input/Output Status, item 5: shows the state of the boiler pump output. Useful to see whether the control is seeing or sending a signal.

Is it safe to keep using my boiler with code Boiler Pump Status?

Usually yes. Code Boiler Pump Status is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code Boiler Pump Status myself?

You can try one reset (power off for 30 seconds, then on). If Navien code Boiler Pump Status comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code Boiler Pump Status near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NHB-H Installation and Operation Manual, 11.13.2 Viewing Input and Output Status, p.110-111. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.