KeepRite error code Amber 2 flashes on a heat pump means: High stage running (normal). It is also called KeepRite diagnostic code Amber 2 flashes.

Low severityHeat PumpKeepRite *CA/*CH Two-Stage Communicating

Homeowner? What KeepRite code Amber 2 flashes means for you

Usually minor Your heat pump is reporting: High stage running (normal). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code Amber 2 flashes mean?

Two flashes, then a pause, repeated. A two-stage outdoor unit is running at high stage. This is normal operation, not a fault.

Applies to: *CA/*CH two-stage communicating outdoor boards

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code Amber 2 flashes

*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960

Other KeepRite Heat Pump codes

CodeMeaning
74No 230 V at compressor
81Low stage thermal lockout
82Thermal lockout (two-stage: high stage)
83Low pressure lockout
84High pressure lockout
Amber 1 flashRunning - cooling / low stage (normal)
Amber 3 flashesOutdoor fan delay after defrost is on (20 s)
Amber 4 flashesOutdoor fan delay after defrost is defeated
Amber 5 flashesBrown-out protection turned off (user setting)
Amber 6 flashesBrown-out protection active (user setting)
Amber LED offStandby - no call (2-wire hookup or indoor unit unpowered)
Amber LED on solidStandby - no call (communicating)

All KeepRite Heat Pump error codes →

KeepRite code Amber 2 flashes: homeowner questions

What does KeepRite code Amber 2 flashes mean?

High stage running (normal). Two flashes, then a pause, repeated. A two-stage outdoor unit is running at high stage. This is normal operation, not a fault.

Is it safe to keep using my heat pump with code Amber 2 flashes?

Usually yes. Code Amber 2 flashes is normally minor, but if it keeps coming back have it checked.

Can I reset KeepRite code Amber 2 flashes myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code Amber 2 flashes comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code Amber 2 flashes near me?

Aurora Star Tech Inc. repairs KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: KeepRite ICP split A-C + HP (R-410A & R-22) Application Guideline and Service Manual 421 08 5400 04, Table 17 Troubleshooting, p.59-60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.