Goodman Error Code L6F: Last 6 faults (view and clear) (Furnace)
Goodman error code L6F on a furnace means: Last 6 faults (view and clear). It is also called Goodman diagnostic code L6F.
Homeowner? What Goodman code L6F means for you
Usually minor Your furnace is reporting: Last 6 faults (view and clear). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code L6F mean?
Menu item that shows the last 6 stored fault codes, newest first. The wiring diagram note also says the last 6 can be recalled by pressing the switch for more than 2 seconds while the furnace is in standby with no thermostat call.
Applies to: GM9S96/AM9S96, GM9S80/AM9S80 and GM9C96/AM9C96 furnaces (7-segment control)
Goodman models that use code L6F
Show all 80 models
AC9C96AC9S800403ANAC9S800603ANAC9S800804BNAC9S800805CNAC9S801005CNAC9S960403BNAC9S960603BNAC9S960804CNAC9S961005CNAC9S961205CNAC9S961205DNAM9C96AM9C960303ANAM9S800403ANAM9S800603ANAM9S800603BNAM9S800604BNAM9S800803BNAM9S800804BNAM9S800804CNAM9S800805CNAM9S801005CNAM9S801205DNAM9S920403ANAM9S920603BNAM9S920803BNAM9S920804CNAM9S920805CNAM9S921004CNAM9S921005CNAM9S921205DNAM9S960403ANAM9S960603BNAM9S960803BNAM9S960804CNAM9S960805CNAM9S961004CNAM9S961005CNAM9S961205DNGC9C96GC9S800403ANGC9S800603ANGC9S800804BNGC9S800805CNGC9S801005CNGC9S960403BNGC9S960603BNGC9S960804CNGC9S961005CNGC9S961205CNGC9S961205DNGM9C96GM9C960303ANGM9S800403ANGM9S800603ANGM9S800603BNGM9S800604BNGM9S800803BNGM9S800804BNGM9S800804CNGM9S800805CNGM9S801005CNGM9S801205DNGM9S920403ANGM9S920603BNGM9S920803BNGM9S920804CNGM9S920805CNGM9S921004CNGM9S921005CNGM9S921205DNGM9S960403ANGM9S960603BNGM9S960803BNGM9S960804CNGM9S960805CNGM9S961004CNGM9S961005CNGM9S961205DN
Other Goodman Furnace codes
| Code | Meaning |
|---|---|
| Err | Active alarm menu |
| FAn | Continuous fan |
| gH | Gas heat, single stage |
| gH1 | Gas heat, low stage |
| gH2 | Gas heat, high stage |
| IdL | Idle - no call |
| rFd | Reset to factory defaults |
All Goodman Furnace error codes →
Goodman code L6F: homeowner questions
What does Goodman code L6F mean?
Last 6 faults (view and clear). Menu item that shows the last 6 stored fault codes, newest first. The wiring diagram note also says the last 6 can be recalled by pressing the switch for more than 2 seconds while the furnace is in standby with no thermostat call.
Is it safe to keep using my furnace with code L6F?
Usually yes. Code L6F is normally minor, but if it keeps coming back have it checked.
Can I reset Goodman code L6F myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code L6F comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code L6F near me?
Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- Control display blank, furnace dead - Goodman/Amana 9-speed ECM furnaces Goodman · Furnace
- No heat - Goodman/Amana 9-speed ECM furnaces Goodman · Furnace
- Poor combustion / flame problems - Goodman/Amana GM9C96 Goodman · Furnace
- Reset the furnace control to factory defaults (rFd) Goodman · Furnace
- View and clear the last 6 stored faults (L6F) Goodman · Furnace
Source: GM9S96 service RS6612022r1, LED Display Menu p.27 and chart p.29; GM9S80 service RS6621008r2, LED Display Menu p.30 and chart p.32; GM9C96 service RS6612020r1, LED Display Menu p.33 and chart p.35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.