Goodman Error Code HP: Compressor heat, single stage (Air Handler)

Updated · by Aurora Star Tech Inc.

Goodman error code HP on a air handler means: Compressor heat, single stage. It is also called Goodman diagnostic code HP.

Low severityAir HandlerGoodman/Amana ComfortBridge AVPTC/MBVC

Homeowner? What Goodman code HP means for you

Usually minor Your air handler is reporting: Compressor heat, single stage. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code HP mean?

Shown while a single-stage heat pump is heating.

Applies to: AVPTC / MBVC ComfortBridge air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code HP

Show all 21 models

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Other Goodman Air Handler codes

CodeMeaning
Ed0No shared data on the network
Ed1Invalid shared data
Ed4Shared data rejected by the control
FAnConstant fan
FCLFault recall (outdoor communicating units)
Flashing optionMenu option flashing = not yet selected
HP1Compressor heat, low stage (comm)
HP2Compressor heat, high stage (comm)
HtElectric heat, single stage
Ht1Electric heat (Ht1)
Ht2Electric heat, high stage
IdlIdle - no call

All Goodman Air Handler error codes →

Goodman code HP: homeowner questions

What does Goodman code HP mean?

Compressor heat, single stage. Shown while a single-stage heat pump is heating.

Is it safe to keep using my air handler with code HP?

Usually yes. Code HP is normally minor, but if it keeps coming back have it checked.

Can I reset Goodman code HP myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code HP comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code HP near me?

Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Goodman ComfortNet ASXC-DSXC-GSXC / ASZC-DSZC-GSZC / AVPTC-MBVC service, Air Handler Display (B*) system status table p.63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.