Carrier Error Code 16: Lost communication with user interface (Heat Pump)
Carrier error code 16 on a heat pump means: Lost communication with user interface. It is also called Carrier diagnostic code 16.
Homeowner? What Carrier code 16 means for you
Check, then call Your heat pump is reporting: Lost communication with user interface. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Carrier error code 16 mean?
Amber STATUS light flashes 16: the outdoor board no longer hears the Infinity user interface.
Applies to: Carrier 25HNB6/25HNB9 two-stage HP; single-stage communicating HP
Common causes of Carrier code 16
- Loose or broken ABCD wiring
- Wiring fault at indoor unit or UI
- UI or indoor unit without power
Carrier models that use code 16
25HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB960
Other Carrier Heat Pump codes
All Carrier Heat Pump error codes →
Carrier code 16: homeowner questions
What does Carrier code 16 mean?
Lost communication with user interface. Amber STATUS light flashes 16: the outdoor board no longer hears the Infinity user interface.
Is it safe to keep using my heat pump with code 16?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Carrier code 16 myself?
You can try one reset (power off for 30 seconds, then on). If Carrier code 16 comes back, the cause is still there and a licensed technician should check it.
Who can fix Carrier code 16 near me?
Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Carrier Residential AC & HP Application Guideline and Service Manual 24-25-9SM (text export), Table 14 Status Codes / Table 18 Troubleshooting. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.