Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code 16: Lost communication with user interface (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code 16 on a heat pump means: Lost communication with user interface. It is also called Carrier diagnostic code 16.

Medium severityHeat PumpCarrier 2-stage 24ANB/25HNB · Carrier single-stage communicating HP

Homeowner? What Carrier code 16 means for you

Check, then call Your heat pump is reporting: Lost communication with user interface. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code 16 mean?

Amber STATUS light flashes 16: the outdoor board no longer hears the Infinity user interface.

Applies to: Carrier 25HNB6/25HNB9 two-stage HP; single-stage communicating HP

Common causes of Carrier code 16

  • Loose or broken ABCD wiring
  • Wiring fault at indoor unit or UI
  • UI or indoor unit without power
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code 16

25HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB960

Other Carrier Heat Pump codes

CodeMeaning
1 longCapacity limited - one long flash
2Normal operation - 2 flashes (high stage)
3Three flashes - outdoor fan delay after defrost active (24ANB/25HNB)
4Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
5Five flashes - brownout protection setting (24ANB/25HNB)
6Six flashes - brownout protection setting (24ANB/25HNB)
25Invalid model plug / inverter size
31High pressure switch open
32Low pressure trip
33Lost inverter communication
45Outdoor control board failure
46Brownout

All Carrier Heat Pump error codes →

Carrier code 16: homeowner questions

What does Carrier code 16 mean?

Lost communication with user interface. Amber STATUS light flashes 16: the outdoor board no longer hears the Infinity user interface.

Is it safe to keep using my heat pump with code 16?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code 16 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code 16 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code 16 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier Residential AC & HP Application Guideline and Service Manual 24-25-9SM (text export), Table 14 Status Codes / Table 18 Troubleshooting. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977