Lennox Error Code Green OFF / Red SLOW flash: Low pressure fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code Green OFF / Red SLOW flash on a heat pump means: Low pressure fault. It is also called Lennox diagnostic code Green OFF / Red SLOW flash.

Medium severityHeat PumpLennox EL16KP1 · Lennox ML14KP1

Homeowner? What Lennox code Green OFF / Red SLOW flash means for you

Check, then call Your heat pump is reporting: Low pressure fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code Green OFF / Red SLOW flash mean?

The low pressure switch (S87, opens at 25 +/- 5 psig, closes at 40 +/- 5 psig) opened and the control stopped the compressor and counted one strike. It is ignored during defrost, for 90 s after defrost, for 90 s after compressor start in TEST mode, and for 10 minutes of compressor run when ambient is below 15°F. Two LP trips in a row in heating start a defrost.

Applies to: Lennox EL16KP1 (Elite) and ML14KP1 (Merit) R-454B heat pumps, sizes -018 to -060, demand defrost control A108 (CMC1)

Common causes of Lennox code Green OFF / Red SLOW flash

  • Restricted airflow over the indoor or outdoor coil (dirty coil, filter, blocked fan)
  • Wrong refrigerant charge
  • Wrong metering device installed or expansion valve not working properly

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code Green OFF / Red SLOW flash

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
Green & Red simultaneous SLOW flashNormal operation or standby
Green FAST flash / Red OFFDischarge sensor lockout
Green FAST flash / Red ONDischarge line temperature lockout
Green OFF / Red FAST flashDischarge sensor fault
Green OFF / Red OFFNo power to the demand defrost control
Green OFF / Red ONLow pressure lockout
Green ON / Red OFFHigh pressure lockout
Green ON / Red ONDemand defrost control failure
Green SLOW flash / Red OFFHigh pressure fault
Green SLOW flash / Red ONDischarge line temperature fault
Red LED on / Green LED offInverter board normal (no fault)
TEST pins (P1)Defrost control TEST pins (field test jumper)

All Lennox Heat Pump error codes →

Lennox code Green OFF / Red SLOW flash: homeowner questions

What does Lennox code Green OFF / Red SLOW flash mean?

Low pressure fault. The low pressure switch (S87, opens at 25 +/- 5 psig, closes at 40 +/- 5 psig) opened and the control stopped the compressor and counted one strike. It is ignored during defrost, for 90 s after defrost, for 90 s after compressor start in…

Is it safe to keep using my heat pump with code Green OFF / Red SLOW flash?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code Green OFF / Red SLOW flash myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code Green OFF / Red SLOW flash comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code Green OFF / Red SLOW flash near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox EL16KP1 Unit Information 100195 / ML14KP1 Unit Information 100108, Table 4 Demand Defrost Control (A108) Diagnostic LEDs, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.