Lennox Error Code 32: Device resetting (Air Handler)
Lennox error code 32 on a air handler means: Device resetting. It is also called Lennox diagnostic code 32.
Homeowner? What Lennox code 32 means for you
Usually minor Your air handler is reporting: Device resetting. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code 32 mean?
A component is resetting itself, often during a power outage or fluctuation (information for dealer only). S30/S40 thermostat alert code 32.
Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems
Common causes of Lennox code 32
- Power fluctuation
- Overloaded transformer
- Low 24 VAC at device
A technician checks these and 1 other possible causes on site before replacing any part.
Other Lennox Air Handler codes
All Lennox Air Handler error codes →
Lennox code 32: homeowner questions
What does Lennox code 32 mean?
Device resetting. A component is resetting itself, often during a power outage or fluctuation (information for dealer only). S30/S40 thermostat alert code 32.
Is it safe to keep using my air handler with code 32?
Usually yes. Code 32 is normally minor, but if it keeps coming back have it checked.
Can I reset Lennox code 32 myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code 32 comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code 32 near me?
Aurora Star Tech Inc. repairs Lennox air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Two horizontal lines on display (soft disable) - Lennox communicating Lennox · Air Handler
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.