Carrier Error Code 86: Fan inverter current lockout (AC)

Updated · by Aurora Star Tech Inc.

Carrier error code 86 on a air conditioner means: Fan inverter current lockout. It is also called Carrier diagnostic code 86.

High severityAir ConditionerAlso Heat PumpCarrier Infinity 19VS 24VNA9

Homeowner? What Carrier code 86 means for you

Call a technician Your air conditioner is reporting: Fan inverter current lockout. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code 86 mean?

Amber STATUS light flashes 86. Outdoor fan motor current kept going too high (elevated from code 63). Type: System malfunction; reset: 5 minutes.

Applies to: Carrier Infinity 19VS variable speed air conditioner 24VNA9 (AOC control + inverter)

Common causes of Carrier code 86

  • Sudden supply voltage change
  • Fan blade or motor restricted
  • Intermittent harness plug connection

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code 86

24VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960

Other Carrier AC codes

CodeMeaning
77Maximum power mode - compressor current
79Compressor / inverter fault (failed start)
81Low stage thermal lockout
82Suction over temperature lockout
83Low pressure lockout (4 hours)
84High pressure lockout (4 hours)
88Compressor / inverter lockout
91Inverter DC over voltage (event)
92Inverter DC under voltage (event)
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout

All Carrier Air Conditioner error codes →

Carrier code 86: homeowner questions

What does Carrier code 86 mean?

Fan inverter current lockout. Amber STATUS light flashes 86. Outdoor fan motor current kept going too high (elevated from code 63). Type: System malfunction; reset: 5 minutes.

Is it safe to keep using my air conditioner with code 86?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code 86 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code 86 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code 86 near me?

Aurora Star Tech Inc. repairs Carrier air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.